EEM View is a completely new concept system in the world which delivers fluorescence, reflection spectra and these images simultaneously. To make it possible, AI technology is applied to analyze data with a special algorithm*1. This measurement is possible by installing the EEM View Accessory on the F-7000 / 7100 Fluorescent Spectrophotometer.*1 The spectral analysis algorithm was developed in joint research by Professor Imari SATO and Associate Professor Yinqiang ZHENG of the National Institute of Informatics.* "EEM" is a trademark of Hitachi High-Tech Analysis Corporation, registered in Japan and China.
Product Description

Features

What is EEM view?

EEM® View -CMOS camera imaging system for Fluorescence Spectrophotometer-

New technology capable of capturing fluorescence and reflection images and spectra of a sample simultaneously.

Measurement of spectrum data for samples (spectral and fluorescence properties).

Captures images under white light or monochromatic light
(area: Φ20 mm, wavelength range: 380 to 700 nm)

Displays separated fluorescence and reflection images obtained using an analysis algorithm that applies AI technology*1

Displays spectra for each partition in an image*1
(fluorescence spectrum and reflection spectrum)

*1The spectral analysis algorithm was developed in joint research by Professor Imari SATO nd Associate Professor Yinqiang ZHENG of the National Institute of Informatics.

EEM® View -CMOS camera imaging system for Fluorescence Spectrophotometer-


Overview

- Fluorescence Spectrophotometer equipped with CMOS camera imaging system -
Uniform illumination system using an integrating sphere

Captures fluorescence and reflection images and spectra of samples simultaneously!

Diffusion of illumination using integrating sphere

Highly uniform illumination of samples

Dual detection using fluorescence spectroscope and CMOS camera

A spectrofluorometric microscope is an option that can be attached to the sample chamber of the existing Model F-7100 fluorescence spectrophotometer equipped with CMOS camera.

EEM® View -CMOS camera imaging system for Fluorescence Spectrophotometer-

Simple mounting which supports many types of samples!

Simple mounting means just placing the sample on top of the integrating sphere!

EEM® View -CMOS camera imaging system for Fluorescence Spectrophotometer-

EEM® View -CMOS camera imaging system for Fluorescence Spectrophotometer-

Plate sample: Mount sample using the quartz window

Powder sample: Fill the powder sample Petri dish with powder, and mount the sample. In addition, the powder cell included with the separate optional solid sample holder can be used.

EEM® View -CMOS camera imaging system for Fluorescence Spectrophotometer-

A fluorescence standard sample is included for alignment confirmation.

The included reference white plate (100%) and blank plate (0%) are used to carry out calibration. These are used to calibrate the fluorescence intensity and the reflectance, and to correct the in-plane brightness distribution in the image.


Applications

Fluorescence properties and morphology of microstructured material

A fluorescent reflective sheet with a microstructure to improve its visibility was measured.

EEM® View -CMOS camera imaging system for Fluorescence Spectrophotometer-

Simultaneous capture of spectrum data and image

EEM® View -CMOS camera imaging system for Fluorescence Spectrophotometer-

The sample is illuminated with monochromatic light at wavelengths of 360 to 700 nm and with white light. An image is captured under each illumination condition, and the fluorescence spectrum is simultaneously acquired by the fluorescence-side spectroscope. After measurement, the 3-D fluorescence spectra are displayed (excitation wavelength, fluorescence wavelength, and fluorescence intensity). An enlarged image and fluorescence and reflection spectra for each partition can be displayed using the dedicated analysis software. The reflection and fluorescence distribution of samples with in-plane nonuniformity can be captured as images and spectra.

Spectral calculation and display of each partition (fluorescence and reflection)

EEM® View -CMOS camera imaging system for Fluorescence Spectrophotometer-

EEM® View -CMOS camera imaging system for Fluorescence Spectrophotometer-

Separated image display (fluorescence and reflection)

Separation of a captured image into a reflected light image and a fluorescence image

EEM® View -CMOS camera imaging system for Fluorescence Spectrophotometer-

EEM® View -CMOS camera imaging system for Fluorescence Spectrophotometer-

A captured image was separated into a reflected light image and a fluorescence image using an image separation algorithm. The reflection image was orange and the fluorescence image was green. The separated images correspond to the reflection spectrum and fluorescence spectrum, respectively, and by summing the orange reflection image and the green fluorescence image, the sample appears yellowish. It was found that the in-plane optical characteristics (optical pattern) in the reflection image and the fluorescence image were different. When the image was enlarged, it could be seen that the microstructure of the reflecting plate had a period of about 200 μm.


Specifications

Function

ItemDescription
EEM View mode (Measurement mode)Measurement of 3-D fluorescence spectrum
Monochromatic light imaging
White light imaging
Preview imaging
Data processing sectionThumbnail displays
3-D fluorescence spectrum display (contour lines, gradation)
Excitation / fluorescence spectrum display
Image zoom function
Partitioned display (1×1, 2×2, 3×2, 4×4, 5×5)
Spectral calculation and display for each partition (fluorescence and reflection)*1
Separated image display (fluorescence and reflection)*1

*1The spectral analysis algorithm was developed in joint research by Professor Imari SATO and Associate Professor Yinqiang ZHENG of the National Institute of Informatics.

Specification

ItemDescription
Irradiation wavelength360 to 700 nm
CameraColor (RGB) CMOS sensor
InterfaceUSB 3.0
Effective number of pixels1920×1200 (H×V)
Photographable wavelengths380 to 700 nm

*Main specifications for the photometer conform to those of the fluorescence spectrophotometer main unit.

Example of configuration

NameP/N (Part Number)
F-7100 Fluorescence Spectrophotometer5J1-0041 / 5J1-0042
EEM View Accessory5J0-0570
R928F Photomultiplier650-1246
Substandard light source5J0-0135 / 5J0-0136